NOTE: If you wish to combine an IP element and a L2 element for a classifier, the L2 element’s 
EtherType must set configured as 0x0800. The following is an example of a L2 element to match 
VLAN 1: 
 ERS5500-48T(config)#qos l2-element 1 vlan-min 1 vlan-max 1 ethertype 0x800 
b)   Adding a Classifier 
To add a new classifier, enter the following command: 
 ERS5500-48T(config)#qos classifier <1-64000> set-id <1-64000> name <name> 
element-type <ip|l2> element-id <1-64000> 
 
Where element-id = IP element or L2 element ID.  
Example: 
Adding an IP element to a classifier: 
 ERS5500-48T(config)#qos classifier 1 set-id 1 name class_1 element-type ip 
element-id 1 
Adding an IP element and a L2 element to a classifier: 
 ERS5500-48T(config)#qos classifier 2 set-id 2 name class_2 element-type ip 
element-id 2 
 ERS5500-48T(config)#qos classifier 3 set-id 2 name class_2 element-type l2 
element-id 1 
c)  Adding a Classifier Block 
To add a new classifier block, enter the following command: 
 ERS5500-48T(config)#qos classifier-block <1-64000> block-number <1-64000>  
name <name> set-id <1-64000> 
Example: 
The following commands add classifiers 1 and 4 to classifier block 1. 
 ERS5500-48T(config)#qos classifier-block 1 block-number 1 name block_1 set-id 1 
 
ERS5500-48T(config)#qos classifier-block 2 block-number 1 name block_1 set-id 4