Chapter 4 Troubleshooting
209418-A
In both situations, the BayStack 420 Switch “autosenses” the speed of the 
connected station and, by default, reverts to half-duplex mode. If the connected 
station is operating in full-duplex mode, it cannot communicate with the switch.
To correct this mode mismatch problem:
1
Use the Port Configuration screen to disable autonegotiation for the suspect 
port (see 
).
2
Manually set the Speed/Duplex field to match the speed/duplex mode of the 
connected station (see 
 on 
).
You may have to try several settings before you find the correct speed/duplex 
mode of the connected station.
If the problem persists:
1
Disable the autonegotiation feature at the connected station.
2
Manually set the speed/duplex mode of the connected station to the same 
speed/duplex mode you have manually set for the BayStack 420 Switch port.
Port interface
Ensure that the devices are connected using the appropriate crossover or 
straight-through cable (see 
), or that autonegotiation or autopolarity is active.