Nortel Networks 10BASE-T Manual Do Utilizador

Página de 330
Using the BayStack 410-24T 10BASE-T Switch
4-4
309985-C Rev 00
Diagnosing and Correcting the Problem
Before you perform the problem-solving steps in this section, cycle the power to 
the BayStack 410-24T switch (disconnect and then reconnect the AC power cord); 
then, verify that the switch follows the normal power-up sequence.
This automatic process is a temporary safeguard only. If 
the stack configuration loses power, the temporary base 
unit will not power up as the base unit when power is 
restored. For this reason, you should always assign the 
temporary base unit as the base unit (set the Unit Select 
switch to Base) until the failed unit is repaired or replaced.
Link
10 Mb/s port 
speed indicator
Green
On
The corresponding port is set to operate at 10 Mb/s and 
the link is good.
Green
Blinking
The corresponding port has been disabled by software.
Off
The link connection is bad or there is no connection to 
this port.
Activity
Port activity
Green
Blinking
Indicates network activity for the corresponding port. A 
high level of network activity can cause the LEDs to 
appear to be on continuously.
Warning: 
To avoid bodily injury from hazardous electrical current, never 
remove the top cover of the device. There are no user-serviceable components 
inside.
Vorsicht:
 Um Verletzungsgefahr durch einen elektrischen Stromschlag 
auszuschließen, nehmen Sie niemals die obere Abdeckung vom Gerät ab. Im 
Geräteinnern befinden sich keine Komponenten, die vom Benutzer gewartet 
werden können.
Avertissement:
 Pour éviter tout risque d'électrocution, ne jamais retirer le 
capot de l'appareil. Cet appareil ne contient aucune pièce accessible par 
l'utilisateur.
Table 4-1.
BayStack 410-24T Switch LED Descriptions
 (continued)
Label
Type
Color
State
Meaning