Description of the device 
 
2.3 RESET button 
 
SCALANCE XB-200 
16
 
Operating Instructions, 02/2015, C79000-G8976-C359-01 
2.3 
RESET button 
Position 
The "RESET" button is located on the rear of the SCALANCE XB-200. 
 
Figure 2-1 
Position of the "RESET" button, for example on the SCALANCE XB213-3 
Resetting the device to factory defaults 
 
 
Note 
If you reset, all the changes you have made will be overwritten by factory defaults. 
 
To reset the device to the factory defaults, follow the steps below: 
1.  Press the "RESET" button, for example with a screwdriver and keep it pressed for 
approximately 12 seconds. 
After 9 seconds, the fault LED "F" flashes for 3 seconds. 
If you release the button after approximately 12 seconds, the device is restarted and the 
factory settings are restored. 
If you release the button before the 12 seconds have elapsed, the reset is canceled. 
Enabling and disabling the button 