The Avaya Multiservice switches are equipped with diagnostics to: 
Monitor the status of the Primary switch controller.
Monitor the status of a Active element. 
Monitoring of Health Check status messages sent between the 
Active and Standby supervisors. 
If the Active supervisor fails, the Standby supervisor assumes supervisor 
operation. Information about a failed Supervisor (CPU) displays in the CPU 
Redundancy Status Web page.
If the Primary controller fails, the redundant controller takes over switch 
controller operation. When an element fails, diagnostics run automatically 
to test the hardware. Information about a failed controller or element 
displays in the Switch Fabric Status Web page. The redundant element takes 
over the function of the failed element until it is replaced.
* Note:  In the event that the Primary switch controller fails, the switch 
will reset and record an entry of the event in the shutdown log.
If the Active element fails, the Active and Standby Supervisor 
modules can no longer communicate, or be synchronized. No 
health messages will be passed. However, the Standby 
Supervisor module will become Active if the current Active 
Supervisor module fails.