Avaya 580 Manual Do Utilizador

Página de 782
Document No. 10-300077, Issue 2
10-5
Configuring Redundancy Options
Installing and Enabling Redundant Hardware 
The standard switch configuration does not include a redundant controller 
or element. The correct process is to:
Install the redundant hardware. See 
Enable the redundant hardware by using either the Web Agent or the 
CLI. See “
.”
After the redundant hardware is enabled, the applicable redundant 
component takes over if either a controller or any element fails.
Installing Redundant Hardware
To install redundant hardware:
1.  Turn off all of the switch power supplies.
2.   Replace the Primary switch controller with the new switch controller. 
This ensures that the switch checks the status of the new switch 
controller.
3.  Insert the previously Primary switch controller into the Redundant 
Controller Slot 1 (see 
 for a P580 or 
 for a P882).
* Note:  Controllers and elements are keyed to ensure that a controller is 
not inserted into an element slot.
4.  Install the redundant element into the redundant element slot 0 for the 
P580, (see 
), or slot 6 for the P882, (see 
).
5.  Turn on the switch power supplies and log in.
6.  Enable the Redundant Hardware as described in the next section.