Avaya M770 Manual Do Utilizador

Página de 338
Chapter 14
Managing the LECS
192
Avaya M770 ATM Switch User’s Guide
To change the location and type of the local LECS, use the
 
lane lecs location 
local
 
command:
Remote LECS
When creating or changing to a remote LECS:
If a local LECS already exists on the switch then you are warned that it will be 
deleted and the switch will look for a LECS at the specified remote address.
To change the location of the remote LECS, use the
 lane lecs remote 
command:
Note:  
Changing the LECS location may disrupt all LANE connections and any 
change will take effect immediately.
Command:
M15-155s8:/>lane lecs location local {wka | <selector>}[{simple | resilient}]
Parameters
:
wka
simple
An active local simple LECS is created, using the WKA. 
Remote clients that make requests for the WKA will be 
routed to this LECS via PNNI.
<selector>
simple
An active simple LECS is created, using the modules 
address with the specified selector.
wka
resilient
A resilient LECS is created.
This LECS will enter the election process and if elected will 
be the “active LECS”. Remote clients that make requests 
for the WKA will be routed to this LECS via PNNI.
<selector>
resilient
A resilient LECS is created, using the modules address with 
the specified selector.
The created LECS will enter the election process and if 
elected will be the active LECS. Modules that are 
configured to use the elected resilient LECS will direct 
clients to this LECS.
Command:
M15-155s8:/>lane lecs location remote {elected | wka | <address>}
Parameters:
remote
elected
Module will wait for notification via a proprietary protocol, of 
the address of the elected resilient LECS.
wka
Module will seek a remote LECS, that is advertising the WKA.
<address>
Module will seek a remote LECS, that is advertising the 
specific ATM address on the network.