LOOPBACK
The T1 CSU ACE supports four types of loopbacks.  With the first two, 
the unit loops the signal received from the network back to the network 
and transmits an unframed 
all 1s
 pattern to the CPE. The signal 
received from the CPE is ignored.
The first type of loopback, Manual Network Loopback (see Table 1), is 
initiated by switching on the 
NET LB 
switch on the back of the unit. The 
NET MAN LB
 LED will turn 
On
 and the loopback will continue until it 
is switched off. See Figure 5 on page 26.
The second type of loopback, Network LB
is activated by sending the 
unit a 
1-in-5 
pattern (10000) from the network side for five seconds. The 
NET RMT LB 
LED will turn 
On
 until it is cleared by sending a 
1-in-3 
pattern
 (100) for five seconds. The patterns may be 
Unframed
 or 
Framed 
(SF or ESF).
The third type of loopback, Manual Equipment Loopback 
(see Table 1), is initiated by the 
Equip LB
 switch on the back of the unit. 
It will continue until 
Equip LB
 is switched off. With the 
Equip LB
, the 
unit loops the signal received from the CPE equipment back to the CPE 
equipment, and transmits an unframed 
all 1s 
pattern to the network. 
The signal received from the network is ignored. The 
EQ MAN LB
 LED 
will illuminate when the loopback is in progress.  See Figure 5 on page 
26
The fourth type of loopback, Equipment Remote Loopback, is activated 
by sending the unit a 1-in-5 pattern (10000) from the CPE side for five 
seconds. The 
EQ RMT LB
 will illuminate until it is cleared by sending a 
1-in-3
 pattern (100) for five seconds. The patterns may be 
Unframed
 or 
Framed
 (SF or ESF).
 
Table 1.  Manual Loopbacks Switch Position Settings
LOOPBACK Type
POSITION 6
POSITION 7
Network
Up
Down
Equipment
Down
Up