Canon Model 6401 B Manual Do Utilizador

Página de 47
Field  Test  Unit  Software
To use the 8k 6264LP  RAM supplied to increase the FTU  memory to 16k
switch  the  FTU  off  and  remove  the  cover  of  the  chip  socket  on  the  back  of
the FTU.
Replace  the  FTU  ROM  with  the  RAM  chip  and  change  the  memory  select
switch  from  ROM  to  RAM.  Replace  the  cover  press  the  reset  button  on  the
back  of  the  FTU   and  switch  on.
R A M   Programs in RAM
Command  Files   Log  Programs
Data
16K
PLOT
RAM/Cassette  RAM/Cassette  Cassette
(in  text  area)
16K
LOAD/COPY/FTUC   RAM/Cassette   RAM/Cassette  Cassette
(in  RAM  file)
24K  PLOT/COPY/FTUC   RAM/Cassette  RAM/Cassette  Cassette
2.3  FTU  INITIALIZATION
If  for  any  reason  the  FTU  programs  need  to  be  loaded,  the  following  proce-
dure should be used:-
1.
2.
3.
4.
5.
6.
7.
Using a pencil, press the RESET button at the rear of the
FTU. (This is a Master Reset, so ALL PROGRAMS WILL
BE  LOST).
Connect  FTU   to  Cassette  Recorder  with  Model  6302A
software  cassette  tape  inserted/rewound  and  ready  to  use.
Press  ON/BREAK  key  on  the  FTU.  The  message  “14940
Bytes  free”  will  appear.  (Note:  at  least  14940  Bytes  are  re-
quired  to  operate  this  software,  more  ‘free’  bytes  are  fme).
Type:- FSET 10000  Return (2300 if using  PLOT/PLOTX)
Type:-  CLOAD  “FTUC”   Return  (system  should  respond  with
‘Found FTUC’  and then continue to read the program
FTUC   from  the  cassette  tape and  store  it  in  the  FTU)
Type:-  SAVE  “FTUC”  Return  (to  save  the  program  FTUC
permanently in the FTU’s  RAM file area.) SAVE
“LOAD/UNLOAD”
Repeat  Steps  5  &  6  above  to  Load  &  Save  programs
“LOAD”  and  “COPY”.  Program  “PLOT”  may  also  be  loaded
if  there  is  sufficient  RAM  in  the  FTU  [in  this  case,  “PLOT”
should  be  LOAD(ed)  and  SAVE(ed)  first,  then  “FTUC”,
“LOAD”  and  “COPY”).
6
Section   2.  GETTING  STARTED