Watlow Electric 2000 Manual Do Utilizador

Página de 40
A p p l i c a t i o n   8  
Wa t l o w   M
I N I
C
H E F
2 0 0 0  
■  
1 3
Configuration Mode Quick Reference
These are the functions, parameters and values included in the Configuration Mode for
this application. You must select Application 8 to access them. For directions, see the
Hardware & Software Setup Guide. The Appendix of that guide includes an explanation
of all parameters and values.
F
unction
Parameter
Value
Your Settings
{Etype} Equipment-Type
[appl`] Application Number 
1 - 28   
8
[a_Loc] Application Number
Security Lock
Yes, No
[Sound] Audible Alarm
0 - 5
[FAn``] Fan Speed
1 spd, 2 spd
[delay] Fan Delay Time
0 - 120 
[SEtUP] Setup 
[`Ç_Ï`] Temperature Display Format
°C or °F 
[time] Time Display Format
MMM:SS, HH:MM, H:MM:SS
(H=Hours, M=Minutes, S=Seconds)
[Chirp] Key Chirp
On, Off
[loc``] Menu Security Lock
Yes, No
[tc```] Thermocouple Type
J, K (shown as [````H]), E
[rtd``] RTD Curve
DIN, JIS
[tconp] WatCurve
TM
Temperature On, 
Off
Compensation
[Ofst1] Temperature Offset, Channel 1
-99 to 99°F (-55 to 55°C)
[tr`lo] Temperature Range Low
0ºF (-18º C) for RTD inputs
32ºF (0ºC) for tc inputs.to [tr`Hi] 
[tr`Hi] Temperature Range High
[tr`lo] to 1200°F (649°C)
[ready] Preheat Ready Feature
Yes, No
[rband] Ready Band
1 to 1200°F (649°C)
[Cloc`] Real Time Clock Display
Yes, No
[plOSS] Power Loss Menu Resume
Yes, No
[al``1] Alarms for channel 1
None, Dev, Proc, Both
[aL`P1] Absolute Process Alarm 1
100 to 1200°F (38 to 649°C)
[aLdL1] Low Deviation Alarm 1
-999 to 0°F (-555 to 0°C)
[aLdH1] High Deviation Alarm 1
0 to 999°F (0 to 555°C)
[tHErl] Thermal
[tyPE`] Temperature Control Type
PID, On-Off
[HYSt1] Hysteresis 1
1 to 99°F (1 to 55°C)
[Pid`U] PID Units
SI, US
[tune1] Auto-tuning 1
on, OFF
[ProP1] Proportional Band 1
1 to 999°F (1 to 555°C)
[rSEt1] Reset (integral) Gain 1
0.00 to 9.99 repeats/minute
[int`1] Integral Gain 1
0.00 to 99.99 minutes/repeat
[rAtE1] Rate (derivative) Gain 1
0.00 to 9.99 minutes
[dEr`1] Derivative Gain 1
0.00 to 9.99 minutes
[CYcL1] PID Cycle Time 1
1 to 60 seconds
[`diag] WatHelp 
Used for equipment troubleshooting and testing. Not used when programming. See the Hardware
Diagnostics
& Software Setup Guide.