Watlow Electric 2000 Manual Do Utilizador

Página de 40
1 4
■  
Wa t l o w   M
I N I
C
H E F
2 0 0 0
A p p l i c a t i o n   8
Program Mode Quick Reference
These are the functions, parameters and values included in the Program Mode for this
application. You must select Application 8 to access them. For menu programming direc-
tions, see the Hardware & Software Setup Guide. The Appendix of that guide includes a
detailed explanation of all parameters and values.
F
unction
Parameter
Value
Your Settings
[M`__] Menu Numbers 1-15
[Stpt1] Set point 1
Temperature range 
Temperature of set point 1.
low to range high.
[Tine1] Time 1
Setting  Time 1, Time 2, Time 3
Run time of set point 1.
and Time 4 to zero invalidates
selected menu.
Format varies based 
on configuration.
[fan`1] Fan 1 Speed
Single Speed: On, Off 
Speed of fan during time 1.
Two Speed: Off, Low, Hi 
[Stpt2] Set point 2
Temperature range
Temperature of set point 2.
low to range high.
[Tine2] Time 2
Setting  Time 1, Time 2, Time 3
Run time of set point 2.
and Time 4 to zero invalidates
selected menu.
Format varies based 
on configuration.
[fan`2] Fan 2
Single Speed: On, Off 
Speed of fan during time 2.
Two Speed: Off, Low, Hi 
[Stpt3] Set point 3
Temperature range
Temperature of set point 3.
low to range high.
[Tine3] Time 3
Setting  Time 1, Time 2, Time 3
Run time of set point 3.
and Time 4 to zero invalidates
selected menu.selected menu.
Format varies based 
on configuration.
[fan`3] Fan 3
Single Speed: On, Off 
Speed of fan during time 3.
Two Speed: Off, Low, Hi 
[Stpt4] Set point 4
Temperature range
Temperature of set point 4.
low to range high.
[Tine4] Time 4
Setting  Time 1, Time 2, Time 3
Run time of set point 4.
and Time 4 to zero invalidates
selected menu.selected menu.
Format varies based 
on configuration.
[fan`4] Fan 4
Single Speed: On, Off 
Speed of fan during time 4.
Two Speed: Off, Low, Hi 
Auto-tuning Note:
Before auto-tuning Application 8, the Set Point 1 of Menu 1 must first be set to a value
that is typical of your application. (See the Hardware & Software Setup Guide for infor-
mation on programming menus.) Then set [tHerl] / [tunE1] to [```on]. After you
accept [```on], by pressing “Enter,” the controller will display [`tunE] while auto-
tuning is taking place.
The controller will cancel the auto-tuning process if it cannot be completed in 80 min-
utes. You can cancel the auto-tuning process at any time by pressing either key C or key
D and accepting [``Off], by pressing “Enter,” when it appears.