Graco U91023 Manual Do Utilizador
Installation
313703A
3
ant provided on all fittings. Tightly clamp the hose
using side-cut or Oetiker pliers.
using side-cut or Oetiker pliers.
6.
Carefully cut the air line opposite the newly installed
fittings as shown in F
fittings as shown in F
7.
Install two clamps (3) and the tee fitting (7) as
shown in F
shown in F
. 6. Tightly clamp the hose using
side-cut or Oetiker pliers.
8.
Use a clamp to install the new hose to the new tee
fitting. Tightly clamp the hose using side-cut or
Oetiker pliers.
fitting. Tightly clamp the hose using side-cut or
Oetiker pliers.
9.
Use a clamp to install new quick-disconnect coupler
onto the other end of the new air hose. Tightly
clamp the hose using side-cut or Oetiker pliers.
onto the other end of the new air hose. Tightly
clamp the hose using side-cut or Oetiker pliers.
10. Install quick-disconnect coupler onto the input fitting
for the breathable air system.
11. Replace breathable air system filters. See breathing
air filter system manual for instructions.
F
IG
. 4: Splice Fittings Installation
F
IG
. 5: Cut Location
3
3
6
5
6
NOTE: The tee fitting may have been installed in
the opposite line in some configurations.
the opposite line in some configurations.
NOTE: The tee fitting may have been installed in
the opposite line in some configurations. Cut the
air line opposite the new fittings.
the opposite line in some configurations. Cut the
air line opposite the new fittings.
F
IG
. 6: New Tee Fitting Install
3
3
7