Installation
313703A
3
ant provided on all fittings. Tightly clamp the hose 
using side-cut or Oetiker pliers. 
6.
Carefully cut the air line opposite the newly installed 
fittings as shown in F
7.
Install two clamps (3) and the tee fitting (7) as 
shown in F
. 6. Tightly clamp the hose using 
side-cut or Oetiker pliers.
8.
Use a clamp to install the new hose to the new tee 
fitting. Tightly clamp the hose using side-cut or 
Oetiker pliers.
9.
Use a clamp to install new quick-disconnect coupler 
onto the other end of the new air hose. Tightly 
clamp the hose using side-cut or Oetiker pliers.
10. Install quick-disconnect coupler onto the input fitting 
for the breathable air system.
11. Replace breathable air system filters. See breathing 
air filter system manual for instructions. 
F
IG
. 4: Splice Fittings Installation
F
IG
. 5: Cut Location
3
3
6
5
6
NOTE: The tee fitting may have been installed in 
the opposite line in some configurations.
NOTE: The tee fitting may have been installed in 
the opposite line in some configurations. Cut the 
air line opposite the new fittings.
F
IG
. 6: New Tee Fitting Install
3
3
7