Maintenance and Adjustments
Speed Adjustment
Speed Settings (DC motors only except 5042)
Speed settings are pre-programmed at the factory for the 
maximum speed. Speed settings should not need adjustment 
with this unit. However, travel speed for the opener can 
be adjusted to a slower speed in both the Open and Close 
directions, to minimize wear on heavier sectional doors.
There are three speed settings available for sectional doors.
Please note that speed may be affected by door weight and 
balance, along with condition of door components and tracks.
Press and hold both up and 
down arrow buttons until 
round LED turns RED, release 
buttons. Round BLUE LED will 
flash 3 times.
 LEDs will now display current UP force setting (See chart).
Press either arrow button until 
desired UP force setting is 
reached.
See Chart
Once setting is chosen, press 
and release. This will lock the 
UP force setting. 
LEDs will now show current DOWN force setting. (See Chart).
Press either arrow button until 
desired DOWN force setting is 
reached. 
See Chart
Once setting is chosen, press 
and release. This will lock the 
DOWN force setting. 
The LEDs will now turn BLUE then off. This confirms 
that both force settings have been set and unit is 
ready for normal operation.
Repeat “Learn Force Limits and Contact Reverse Test” page 8
OFF
BLUE
BLUE
OFFFlashes 
3 Times
OFF
RED
BLUE
PRGM
SET
PRGM
SET
PRGM
SET
PRGM
SET
PRGM
SET
Resetting Travel Limits
See pages 6-7-8 to reset travel limits. Force setting and contact 
reverse test must be performed in the event of a travel limit change.
NOTE: The opener will not close automatically unless the 
Safe-T-Beam® System is installed and Limits are programmed.