4.1  Connection to LPG 
 
Use a pressure regulator and make the connection to the tank according to the 
provisions of standards regulations in force. Make sure that feed pressure conforms to 
the levels shown in the table in Section “5.2 Regulation for LPG ”. 
 
4.2  Ventilation of rooms 
 
 
The hob may be installed only in rooms with permanent ventilation, as required by 
standards regulations in force. The room in which the hob is installed must have 
sufficient air flow to satisfy the requirements of normal gas combustion and of 
necessary air exchange in the room. The air intakes, protected by screens, must be 
appropriately sized (regulations in force) and placed so as not to be blocked in any 
way. 
The room where the oven is installed should be suitably ventilated to avoid 
overheating or excess humidity produced by cooking, and in the case of lengthy use a 
window should be opened or the speed of any ventilators should be increased. 
 
 
4.3  Discharge of combustion products 
 
 
Discharge of combustion products must be guaranteed by means of hoods connected 
to a natural draught flue with certain efficiency, or by means of forced aspiration. 
An efficient aspiration system requires careful planning by a specialist capable of 
installing it, respecting the positions and distances prescribed by standards. After 
installation, the installer must issue a certificate of conformity.