Instructions for the installer 
 
 
26 
5.2  Regulation for LPG 
Loosen screw C and push air regulator D to the 
bottom. 
With a 7 mm wrench, remove nozzle E and 
replace it with the proper one (follow the 
instructions on the reference tables for the type of 
gas to be used). The torque wrench setting of the 
nozzle must not exceed 3 Nm
Regulate the air by sliding regulator D until 
reaching distance “X” shown in the table in 
paragraph “5.4 Regulation of primary air ”. 
Lock regulator D by tightening screw C
 
 
Burner 
Rated 
heating 
capacity 
(kW) 
 
LPG – G30/G31  28/37 mbar 
 
 
Nozzle 
diameter 
1/100 mm
By-pass 
mm 
1/100 
Reduced 
flowrate 
(W) 
Flowrate 
g/h G30 
Flowrate 
g/h G31 
Auxiliary 
1.0 
48 
30(**) 
30 (*) 
450 
73 
72 
Semi rapid 
1.6 
62 
30(**) 
33 (*) 
500 
116 
114 
Medium rapid 
2.3 
75 
40(**) 
40 (*) 
700 
167 
164 
Large rapid 
3.0 
82 
40(**) 
45 (*) 
800 
218 
215 
76 
UR 
3.6 
48 
48 (**)
50 (*) 
1000 
261 
257 
*/**: diameters marked * and ** must be fitted respectively on valves marked * and **shown inpoint “5.6 
Regulation of minimum for natural gas”.
 
 
 
 
CAUTION: for references A and B on 
the lh UR and rh UR burners, see 
drawings at side.
 
     
 
 
5.3  Regulation for natural gas 
The hob has been inspected for G20 (2H) natural gas at a pressure of 20 mbar. To 
allow the unit to work with this type of gas, perform the same operations described in 
paragraph “5.2 Regulation for LPG ”, but choose the nozzles and regulate the primary 
air for natural gas, as shown in the following table and in paragraph “5.4 Regulation of 
primary air ”. 
 
 
Burner 
Rated 
heating 
capacity 
(kW) 
 
Natural gas – G20  20 mbar 
 
 
Nozzle diameter 
1/100 mm 
Reduced flowrate 
(W) 
Auxiliary 
1.0 
73 
400 
Semi rapid 
1.65 
92 
500 
Medium rapid 
2.3 
110 
700 
Large rapid 
3.0 
126 
800 
115 
UR 
3.6 
73 
1000