Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.
Installation – 
Beer Pump Panels 
 Use panel as a template to mark where holes 
should be drilled on cooler wall. Beer pump 
panels should not be installed with a height 
of greater than 5 feet from the cooler floor. A 
height greater than 5 feet will potentially cause 
flow issues and require system re-balancing. 
(Note: Make sure panel is level and pumps are 
in the vertical position).
   Drill 
9
/
64
 
pilot holes in cooler wall. Use fasteners  
  provided in installation kit to mount the beer  
  pump panel to the cooler wall.
Push CO
2
 supply line over barbed CO
2
 supply  
 
inlet. 
(See diagram on page 3). Position clamp  
 
over joint and tighten. Always use 
3
/
8
” I.D.  
 
braided tubing for gas supply line. Gas supply line  
should have drops going to each panel. (Never  
 
connect supply line in a series hook-up. 
 
Push beer line (from trunk housing) over barbed  
liquid outlet on flow reversal valve. (See  
 
diagram on page 3). Position clamp over  
 
joint and tighten.
   Push connector hose over liquid inlet on beer  
  pump flow reversal valve inlet fitting. 
(See  
  diagram on page 3). Position clamp over joint  
  and tighten. (NOTE: Connector hose should not  
  exceed 10 feet in length).  
  Install washer into hex nut on opposite end of  
  connector hose. Connect to top threaded fitting  
  of Perlick Smart Coupler.
 Cut a piece of CO
2
 tubing (red 
9
/
16
” vinyl tubing) 
and push one end onto barbed CO
2
 outlet to 
Keg Couplers (See diagram on page3). Position 
clamp over joint and tighten. Push the other end 
over the barbed gas inlet on the Perlick Smart 
Coupler. Position clamp over joint and tighten.
Important Notes
  CAUTION: If using CO
as a pressure supply for  
 
pumps, pump exhaust must be vented to a well  
 
ventilated area to avoid possible asphyxiation.
  Never use a single keg to supply more than one  
 
beer pump. Using a single keg to supply more  
 
than one pump will create flow problems, pump  
 
burn out or premature Smart Coupler shut-off.
  Pump panels should never be installed more  
 
than 5 (five) feet above the cooler floor. A height  
 
in excess of 5 (five) feet causes additional  
 
pressure drop between the keg and pump inlet  
 
which may cause degassing or premature Smart  
Coupler shut-off.
  Beer pumps must be used in combination with  
 
an empty keg sensing device. If an empty keg  
 
sensing device is not used premature pump  
 
failure will occur.
  If using compressed air as pressure source to  
 
drive pumps, pump and keg regulators need to  
 
be seperated. Air must be clean and dry.
Form No. Z2149A
Rev. 10.11.06