Dacor MOH Manual Do Utilizador

Página de 20
10
1.  Before proceeding, turn off power to the circuit to which 
the oven will be connected at the circuit breaker or fuse 
box.
2.  Position the oven directly in front of the cabinet cutout.
3.  Feed the appliance conduit into the electrical junction 
box and attach it using a UL approved strain relief.
4.  Depending upon local codes, utilize one of three meth-
ods to connect the appliance to the electrical power:
◊  Connect to a four (4) wire electrical system
◊  Connect to a three (3) wire electrical system, where 
local codes permit
◊  Connect to a three (3) wire electrical system with 
external ground, according to local codes.
Connecting to a Four (4) Wire Electrical 
System
1.  Separate the wires coming out of the appliance conduit.
2.  Connect the white wire from the appliance conduit to 
the white (neutral) supply wire in the junction box.
3.  Connect the black wire from the appliance conduit to 
the black (L1) supply wire in the junction box.
4.  Connect the red wire from the appliance conduit to the 
red (L2) supply wire in the junction box.
5.  Connect the green wire from the appliance conduit to 
the green (ground) wire in the junction box.
Installation Instructions
Electrical Service Installation
 WARNING
•  Wire the oven only in compliance with local ordinanc-
es.
•  If the electrical service provided does not meet the 
product specifications, do not proceed with the instal-
lation. Call a licensed electrician to install the required 
wiring.
•  To prevent an electric shock or fire hazard, turn off 
power to the circuit at the circuit breaker or fuse box 
prior to connecting the wiring to the oven.
•  Improper connection of the electrical wiring can cause 
an electric shock hazard and damage the appliance. 
Dacor is not responsible for damages resulting from 
improper installation.
•  Connect the ground terminal (or lead) on the appliance 
to a grounded, metallic, permanent wiring system  or 
grounding conductor.
•  Do not use an extension cord with this appliance. 
Such use may result in fire, electric shock or other per-
sonal injury.
•  Do not install a fuse in the neutral or ground circuit. A 
fuse in the neutral or ground circuit may result in an 
electric shock hazard.
•  The appliance must be connected to the power supply 
with copper wire only. The use of aluminum wire may 
result in unsatisfactory connections.
•  Flexible armored or non-metallic, sheathed copper 
cable (with grounding wire) should be used to connect 
the appliance to the junction box. An UL-listed connec-
tor must be used to directly connect the cable to the 
junction box.
 IMPORtANt
Make sure that the conduit is long enough to allow the 
oven to be pulled out for service without disconnecting it 
from power.
Junction box
Four (4) Wire Junction Box Connection
Cable from circuit breaker 
panel or fuse box
Conduit to 
wall oven
RED
WHITE
BLACK
GREEN
RED
WHITE
BLACK
GREEN
Wire nut
(4 places)