Installation Instructions
Connecting to a Three (3) Wire Electrical 
System - Where Local Codes Permit
 WARNING
Do not connect the green appliance conduit wire to the 
neutral (white) junction box wire unless local building 
codes permit.
1.  Separate the wires coming out of the appliance conduit.
2.  Connect the green and white wires from the appliance 
conduit to the white (neutral) supply wire in the junction 
box.
3.  Connect the black wire from the appliance conduit to 
the black (L1) supply wire in the junction box.
4.  Connect the red wire from the appliance conduit to the 
red (L2) supply wire in the junction box.
Junction box
three (3) Wire Junction Box Connection -
(Where Local Codes Permit)
Cable from circuit breaker 
panel or fuse box
Conduit to 
wall oven
RED
WHITE
BLACK
GREEN
RED
WHITE
BLACK
Wire nut
(3 places)
Connecting to a Three (3) Wire Electrical 
System with External Ground - Where Local 
Codes Permit
 WARNING
•  Do not connect the green appliance wire to the junc-
tion box or to a cold water pipe unless local building 
codes permit.
•  Do not ground the appliance to a gas supply pipe or 
hot water pipe.
•  If connecting the ground wire to a grounded cold water 
pipe, connect using a separate copper grounding 
wire (No. 10 minimum) and a clamp with an external 
grounding screw. The grounded cold water pipe must 
have metal continuity to electrical ground and must not 
be interrupted by insulating materials. Any insulating 
materials must be jumped, with a minimum, 4 AWG 
wire to establish continuity to ground.
 NOtE
If the junction box has been properly grounded by a 
licensed electrician, the green (ground) wire from the 
appliance conduit may be connected to the junction box 
using a loop terminal.
See the diagram on the following page. To connect the 
green appliance conduit wire to a grounded cold water 
pipe:
1. Separate the wires coming out of the appliance conduit.
2. Connect the white wire from the appliance conduit to the 
white (neutral) supply wire in the junction box.
3. Connect the black wire from the appliance conduit to the 
black (L1) supply wire in the junction box.
4. Connect the red wire from the appliance conduit to the 
red (L2) supply wire in the junction box.
5. Connect the green wire from the appliance conduit to a 
grounded cold water pipe as shown. Jumper any insulating 
materials as shown above with a length of No. 4 copper 
wire. Securely clamp the wire to bare metal at both ends.
Clamps
Bare metal
Meter
No. 4 copper 
wire
Metal water
pipe
Insulated Pipe Jumper