  PROBLEM
         POSSIBLE CAUSE
 REMEDY
[5] No water
a) Water Supply Line
1. Water pressure too low and
1. Check and get
     comes from
    water level in Water Tank
     recommended pressure.
     Spray Tubes.
    too low.
     Water Pump
b) Water Solenoid
1. Dirty mesh filter or orifice
1. Clean.
     will not start, or       Valve
    and water level in Water
     freeze cycle
    Tank too low.
     time is too
c) Water System
1. Water leaks.
1. Check connections for
     short.
     water leaks, and replace.
2. Clogged.
2. Clean.
3. Pump Out Check Valve
3. Check assembly and
    leaking by.
     clean.
d) Pump Motor
1. Motor winding opened.
1. Replace.
2. Bearing worn out.
2. Replace.
3. Wiring to Pump Motor.
3. Check for loose
    connection or open, and
    replace.
4. Defective Capacitor.
4. Replace.
5. Defective or bound impeller. 5. Replace and clean.
6. Mechanical Seal worn out.
6. Check and replace.
e) Controller Board
1. Defective.
1. See “II.2. [e] CHECKING
    CONTROLLER BOARD.”
[6] Fan Motor will
a) Fan Motor
1. Motor winding opened.
1. Replace.
     not start, or is
2. Bearing worn out.
2. Replace.
     not operating.
3. Wiring to Fan Motor.
3. Check for loose
     connection or open, and
               replace.
4. Defective Capacitor.
4. Replace.
5. Fan blade bound.
5. Check and replace.
b) Controller Board
1. Defective.
1. See “II.2. [e] CHECKING
    CONTROLLER BOARD.”
[7] All components a) Refrigerant
1. Undercharged.
1. Check for leaks and
     run but no ice
     recharge.
     is produced.
2. Air or moisture trapped.
2. Replace Drier, and
    recharge.
b) Compressor
1. Defective valve.
1. Replace.
c) Hot Gas Solenoid
1. Continues to open in freeze
1. Check and replace.
    Valve
     cycle.
d) Line Valve
1. Continues to close in
1. Check and replace
     freeze cycle.
e) Water Solenoid
1. Water Solenoid Valve is
1. Check for water leaks
    Valve
     open during freeze.
    with icemaker off.
f) Water Supply Line
1. Condenser water pressure
1. Check and get
                        [Water-cooled model
    too low or off and Pressure
     recommended pressure.
    only]
    Control opens and closes
              frequently.