2. EVAPORATOR IS FROZEN UP
  PROBLEM
         POSSIBLE CAUSE
 REMEDY
[1] Freeze cycle
a) Float Switch
1. Leads short-circuit or
1. Check and replace.
     time is too
    defective switch.
     long.
2. Float does not move freely.
2. Clean or replace.
b) Water Solenoid
1. Diaphragm does not close.
1. Check for water leaks
     Valve
     with icemaker off.
c) Controller Board
1. Defective.
1. See “II.2[e] CHECKING
    CONTROLLER BOARD.”
[2] All ice formed
a) Evaporator
1. Scaled up.
1. Clean.
     on Evaporator b) Water Supply Line
1. Water pressure too low.
1. Check and get
     does not fall
     recommended pressure.
     into bin in
c) Water Filter System
1. Dirty/Restricted.
1. Replace filter.
     harvest cycle.
d) Water Solenoid
1. Dirty mesh filter or orifice.
1. Clean.
    Valve
e) Ambient and/or
1. Too cool.
1. Increase temperature.
    water temperature
f) Line Valve
1. Continues to open in
1. Check operation in
     harvest cycle.
    harvest cycle and replace.
g) Thermistor
1. Out of position or loose
1.  See “V. 11. REMOVAL
     attachment.
    AND REPLACEMENT OF
    THERMISTOR.”
h) Controller Board
1. Defrost Timer is set too
1. Adjust longer, referring
              short.
     to “II. 2. [d] CONTROLS
     AND ADJUSTMENT, 2)
     Defrost Timer.”
2. Defective.
2. See “II. 2.[e] CHECKING
    CONTROLLER BOARD.”
[3] Others
a) Spray Tubes
1. Clogged.
1. Clean.
2. Out of position.
2. Place in position.
b) Water System
1. Dirty.
1. Clean.
c) Refrigerant
1. Undercharged.
1. Check for leaks and
     recharge.
d) Expansion Valve
1. Bulb out of position or
1. Place in position.
    loose attachment.
2. Defective.
2. Replace.
e) Hot Gas Solenoid
1. Coil winding opened.
1. Replace.
     Valve
2. Plunger does not move.
2. Replace.
3. Wiring to Hot Gas Valve.
3. Check for loose
     connection or open, and
     replace.
f) Water Supply Line
1. Too small; requires 1/2" OD 1. Increase water line size.
     line dedicated per machine.
g) Water filter
1. Flow rate too small.
1. Replace with filter that
     has larger flow rate.