Bunn JDF-2N Manual Do Utilizador

Página de 32
23
38310 010406
TROUBLESHOOTING (cont.)
Dispense station not working "refill" 
LED and beep code.
A) 3-Beep - Dispense/Rinse sens-
ing fault.
B) 4-Beep - Dispense/Rinse knob 
mis-positioned.
Refill LED not extinguishing
All  stations  dispense  concentrate 
only
1.  Bottle  adapter  switch  mem-
brane
A)  Dispense/Rinse  switch  mem-
brane shorted out simultaneously.
B)  Dispense/Rinse  switch  mem-
brane open simultaneously.
2. Concentrate lockout (Dipswitch 
#2)  feature  activated  -  locks  out 
station when refill light is ON.
3. Dispense touchpad.
Bottle adapter refill
Main water supply
Internal ON/OFF water valve
Frozen bath
Check  for  moisture  at  3-pin  con-
nector  and  clean.  Apply  electrical 
insulating  compound  or  replace 
defective switch membrane.
Check knob for mis-position or re-
place defective switch membrane.
Check  for  proper  orientation  of 
the  Dispense/Rinse  membrane 
switch.
Hint:  Good  bottle  adapter  switch 
membrane  will  sound  the  beeper 
when you rotate the knob between 
dispense and rinse to indicate closed 
position.
Refill product or turn OFF concen-
trate  lockout  feature  (Dipswitch 
#2)
See Schematics and check corre-
sponding dispense station button 
for continuity - replace touchpad.
Check wire terminals going to the 
probes  for  proper  connection  or 
refill  probes  need  to  be  cleaned 
and rinsed.
NOTE: Door switch resets the "Refill" 
LEDs.
Check for ON position.
Check for ON position.
A)  Compressor  relay/contacts 
shorted - replace relay.
B) Recirculating pump - replace or 
check for kinked flex line.
PROBLEM
PROBABLE CAUSE
REMEDY