ADJUSTMENT
Receiver section
Item
Condition
Measurement
Adjustment
Specifications/
Test equipment
Unit
Terminal
Unit
Parts
Method
Remarks
1.RX BPF
Squelch level: 0
   Adjust
1) Frequency: 145.050MHz
SSG
TX-RX
ANT
VOL
Turn the VOL knob 0.63V
(E, E3)
Oscilloscope
(A/3)
SP
knob
to obtain 0.63V AF
Frequency: 146.050MHz
Distortion meter
output.
(K, K2, M, M2) AF V.M
SSG output: –53dBm (501 uV) Dummy load
SSG MOD: 1kHz
SSG DEV: 3kHz
Switch to Adjustment mode
and carry out the operations
for adjustment item E.
(Refer to page 29)
2) LCD display: BPL
Encoder
Write
Max Sensitivity
Frequency: 136.050MHz
[MENU]
SSG: –119dBm (0.25 uV)
3) SSG: –113dBm (0.501 uV)
Check
12dB SINAD or
more
4) LCD display: BPC
Encoder
Write
Max Sensitivity
Frequency: 146.050MHz
[MENU]
SSG: –119dBm (0.25 uV)
5) SSG: –120dBm (0.22 uV)
Check
12dB SINAD or
more
6) LCD display: BPH
Encoder
Write
Max Sensitivity
Frequency: 160.050MHz
[MENU]
SSG: –119dBm (0.25 uV)
7) SSG: –113dBm (0.501uV)
Check
12dB SINAD or
more
2.IF response 1) Frequency : 144.050MHz
SSG
Check
12dB SINAD or
Check
SSG Frequency: 221.750MHz Oscilloscope
less
SSG output: –60dBm (224uV) Distortion meter
Note: If the
SSG MOD: 1kHz
specification is not
SSG DEV: 3kHz
satisfied, repeat the
AF output: 0.63V/8Ω
operations for
“1. RX BPF
Adjust”.
3.Squelch /
Switch to Adjustment mode
SSG
ANT
S-meter
and carry out the operations
Write
for adjustment item C.
(Refer to page 28)
1) LCD display: SQ1
[MENU]
Write
Note: In the
Frequency: 145.050MHz
Squelch adjust
(E, E3)
ments, all 4
Frequency: 146.050MHz
adjusting points
(K, K2, M, M2)
including the S-
SSG: –125dBm (0.126uV)
meter must be
2) LCD display: SQ2
[MENU]
Write
adjusted.
Frequency: 145.050MHz
      
Squelch
(E, E3)
Frequency: 146.050MHz
(K, K2, M, M2)
SSG: –120dBm (0.22uV)