Over 
Temperature
1. 
The internal temperature is higher
than 
specified normal value 
2. Find a way to reduce the ambient temperature. 
3. Or move the inverter to a cooler environment 
4. If it is not effective, please contact Eaton. 
Relay Failure
DC INJ High
EEPROM 
Failure 
SCI Failure 
High DC Bus
Low DC Bus
Ref 2.5V Fault
DC Sensor 
Fault 
GFCI Failure
1. Disconnect 
ALL PV (+) or PV (-) 
2.  Wait for few seconds 
3.  After the LCD switches off, reconnect and 
check again 
4.  If the message reappears, please contact 
Eaton. 
 
z  If there is no display on the panel, please check PV-input connections.  
If the voltage is higher than 150V, call your local service. 
z  During periods of little or no sunlight, the PV-Inverter may continuously 
start up and shut down. This is due to insufficient power generated to 
operate the control circuits. 
 