Eaton Electrical ETN2000 Manual Do Utilizador

Página de 33
 
9.   Specifications 
Electrical 
Model 
EATON ETN1000 
EATON ETN2000 
Nominal AC power 
1000W 
2000W 
Max. AC power 
(in 10 minutes) 
1100W 2200W 
Input 
Nominal DCV 
360V
DC
 360V
DC
 
Max. open DCV 
    500V
DC
 
    500V
DC
 
MPPT range 
150 to 450V
DC
 
150 to 450V
DC
 
Working range 
100 to 500V
DC
 
100 to 500V
DC
 
Max. input current 
5A
DC
 10A
DC
 
Output 
Operational voltage 
range
 (F/W Setting) 
206~264 V
AC
  
206~264 V
AC
  
Operational frequency 
range
 (F/W Setting) 
49.25~50.75Hz 
 
49.25~50.75Hz  
Current distortion 
<3% 
<3% 
Power factor 
>0.99 
>0.99 
Maximum η 
95% 
96% 
European η 
93% 
95% 
Environment 
Protection degree 
IP 43 
Operating temperature 
-20 to 55ºC 
Humidity 
0 to 95%, non-condensing 
Heat Dissipation 
Convection 
Power consumption 
<7W 
Acoustic noise 
<35dBA 
Communication & Features 
LCD 
1-Line, 16 characters 
Comm. Interface 
RS232 standard, RS485 optional 
F/W upgrade 
Yes, via RS232 
Mechanical 
W
×D×H (mm) 
305x302x120 
Weight (kg) 
11.3 
Normative references 
Grid interface regulation
AS4777 
Safety AS3100 
EMC: EMS/EMI 
EN 61000-6-2 (2005) / EN 61000-6-3 (2007) 
CE 
LVD: 2006/95/EC EMC: 2004/108/EC 
                                                      
1
 
 Regulation voltage range is 200~270 V
AC
 according to AS4777. 
 
 
2
  
Regulation frequency range is 45~55Hz according to AS4777. 
 
31