Lowrance electronic HDS 10 Manual Do Utilizador

Página de 52
31
NMEA 0183 wiring 
HDS-5 & HDS-7 Data Cable
To exchange NMEA 0183 data, the HDS-5 and HDS-7 units have a NMEA 0183 version 2.0 
(RS-422) communication port. Serial Communications Port one can be used to transmit or 
receive NMEA format data. The five wires for the serial communications ports (Data cable) 
are combined with the Power cable to form the Power/Data cable. 
HDS-8 & HDS-10 Data Cable
To exchange NMEA 0183 data, the HDS-8 and HDS-10 units have either one NMEA0183 
version 2.0 (RS-422) communication port, or two NMEA 0183 (RS-232) communication 
ports.  The five wires for the serial communications ports (Data cable) are combined with the 
Power cable to form the Power/Data cable. 
NMEA 0183 Wiring Table
RS-422
HDS
Device
Green RX (-)
Transmit (-)
Orange RX (+)
Transmit (+)
Shield (Ground)
Ground
Yellow TX (+)
Receive (+)
Blue TX (-)
Receive (-)
RS-232 HDS-8 & 10 Only — (COM 1)
HDS
Device
Yellow TX
Receive
Orange RX
Transmit
Shield (Ground)
Ground
RS-232 HDS-8 & 10 Only — (COM 1)
HDS
Device
Blue TX
Receive
Green RX
Transmit
Shield (Ground)
Ground