Figure 14 - Wall Switch Wiring Diagram
Note:
 If any of the original wire as supplied must be replaced, use 18 AWG 
TYPE CL2 (UL) 105 C (25 ft. length MAXIMUM) or equivalent.
OPTIONAL WIRELESS HAND-HELD REMOTE 
CONTROL INSTALLATION
Note:
 If using optional wireless hand-held remote control, the wall 
switch is no longer operational. 
Installing Receiver
1.  Remove the front refractory access panel by lifting up and angling 
out of the firebox opening (see Figure 13) to expose controls.
2.   Disconnect wall switch wires from TH and TH/TP terminals 
on control valve (see Figure 14).
3.  Install remote receiver unit onto mounting bracket using the 
two plastic mounting clips (see Figure 15).
Figure 15 - Installing Remote 
Receiver (Shown from Rear of 
Mounting Bracket)
Receiver 
Mounting Bracket
Plastic 
Mounting 
Clips
Conduit Sleeve
To Safety Circuit
Route Millivolt
Through Gas Line
To Thermopile
Wires (Supplied)
Wall Switch
(Supplied)
(Back View)
IN
TH
TP
THTP
 
IN
OUT
O
F F
P
IL
O
T
ON
Installing 9-Volt Battery in Hand-Held Remote 
Control Unit 
1.  Remove battery cover on back of remote control unit.
2.  Attach terminal wires to the battery (not included). Place battery 
into the battery housing. Note: Only use alkaline battery.
3.   Replace battery cover onto remote control unit.
Figure 17 - Installing Battery in Hand-Held Remote Control Unit 
Battery Cover 
9-Volt 
Battery 
Terminal Wires 
Remote Control Unit 
Battery 
Housing 
Figure  16  -  Installing  Battery 
in Receiver
Battery 
Clip 
9-Volt Battery 
Receiver 
Terminal 
Wires 
INSTALLATION
WALL SWITCH INSTALLATION
The installation of a wall switch allows you to activate the gas 
control valve without the normal household electricity since the 
valve operates on millivolt current supplied by the heat generated 
by the thermopile. To install the wall switch:
1.  Remove the front refractory access panel by lifting up and 
angling out of the firebox opening (see Figure 13).
2.  Use wire and connectors provided. Attach red wire to terminal 
marked TH/TP on control valve. Attach white wire to blade 
connector on open end of safety circuit wiring (see Wiring 
Diagram, page 18).
Note:
 If any of the original wire from the unit control must be re-
placed, use the same type or a higher rated wire (25 ft. maximum 
length).
 WARNING: Do not wire remote wall switch to main 
power supply (Standard 120v household current).
3.  Locate wall switch in a convenient location.
4.  After wire connections are complete, replace refractory access 
panel.
Figure 13 - Removing Front Refractory Access Panel
4.  Connect wires to control circuit. Connect white wire to termi-
nal marked TH/TP on control valve. Connect red wire to male 
blade connector provided at open end of safety circuit wiring 
(see Wiring Diagram, page 18).
5.  Locate the battery clip mounted on the back of the receiver 
(see Figure 16). 
6.  Slide 9-volt battery (not included) through the clip. Note: Only 
use alkaline battery.
7.  Attach the terminal wires to the battery (see Figure 16).
8.  Replace refractory brick access panel.