VENTING INSTALLATION
A B-type venting system must be connected to the appliance for 
venting to the outside of the building.
The following section is provided as a guide to a standard B-type 
vent installation.
Standing codes requirements concerning B-type vent installations 
may vary within your state, province or local codes jurisdiction. 
Therefore, it is recommended that you check with your local build-
ing codes for specific requirements or in absence of local codes, 
follow Section 7.0 of the current National Fuel Gas Code ANSI 
Z223.1/NFPA 54 and in Canada with CAN/CGA B149 for Category 
I systems using double wall B-1 vent pipe.
This gas appliance must be vented to the outdoors only and may not 
be terminated into an attic space or into a chimney flue servicing a 
solid-fuel burning appliance.
This appliance may be vented through a manufactured chimney 
system or a masonry chimney using a B-vent adapter or a chimney 
liner system if all are listed, inspected and approved by local codes 
and/or building authorities.
The examples shown in Figure 10 are typical of most B-vent instal-
lations and codes practices.
Example  1:
  Shows  the  minimum  allowable  system  height  and 
lateral offset for a 60° degree or greater inclination. Code specifies 
that offsets at 60° degrees or greater are considered horizontal and 
must follow the 75% percent rule for lateral to total vertical system 
height. Codes also allows only one offset in the total system when 
at 60° degrees or greater. The total vertical height in this example 
represents the minimum height of 8 feet and therefore the allowable 
lateral is 6 feet when the 75% percent rule applies. If the lateral 
length must exceed 75% then the system must be sized in accordance 
with the Category I venting tables.
Example 2:
 Shows a multiple offset each at 45° degrees of inclina-
tion. Multiple offsets are permitted if they do not exceed 45° degrees 
of inclination. The total lengths of the two offsets are not required 
to meet the 75% percent allowable rule.
Example 3:
 Shows a single offset at 45° degrees of inclination 
and therefore the lateral length at 10 feet of offset does not have to 
meet the 75% percent rule.
In each case the offsets must be supported and firestops must be 
positioned wherever the vent must pass through a sub-floor, ceiling 
joist or an attic overhang. The vent pipe must terminate vertically 
into a listed type vent cap and extend a sufficient height through 
an approved roof flashing, roof jack or a roof thimble. At all points 
the listed clearances must be maintained.
Maintain
Listed
Clearance
12' Min.
12' Min.
45
45
6'
8'
12' Min.
60
45
Position
Firestop
Position
Firestop
Position
Firestop
Listed
Vent Cap
Listed
Vent Cap
Listed
Vent Cap
Maintain
Listed
Clearance
Maintain
Listed
Clearance
Maintain
Listed
Clearance
Maintain
Listed
Clearance
Maintain
Listed
Clearance
Support Each
Lateral At
Least Every
Six (6) Feet
Maintain
Listed
Clearance
10'
EXAMPLE 3
EXAMPLE 2
EXAMPLE 1
Figure 10 - Typical B-Vent Configuration