Regency IG35-LPG Manual Do Utilizador

Página de 31
11
Regency IG35 Gas Inbuilt Fireplace
Conversion Kit #486-967 for NG to ULPG
THIS  CONVERSION  MUST  BE  DONE  BY  A  QUALIFIED  GAS  FITTER  IF  IN  DOUBT  DO  NOT  DO  THIS  CONVERSION !!
Conversion Kit 486-967 Contains:
Qty. Part #  Description
1 904-345  Burner Orifi ce #53
1  918-273  Red "ULPG" label
1  918-272  Label "Converted to ULPG"
1 918-542  Instruction Sheet
1)  Shut off the gas supply and unplug the power 
cord. 
2)  Remove the front door.
3) Remove logs. 
4)  Remove the rear log tray by removing the 2 
screws. (Log tray must be rotated to clear 
the burner.)
Control Box
Cover
Antenna
13) Remove the control  box cover  by  undoing the 
3 screws.  Maneuver through  antenna.
Jumper Location
Jumper
14) Remove the jumper using a plier.
5)  Remove the grate.
6)  Remove the burner and adjust the aeration 
setting to 15 mm fully open.
7)  Remove burner orifi ce with a 1/2" wrench 
and discard. Use a wrench to hold on to the 
elbow behind the orifi ce.
8)  Reinstall new burner orifi ce ULPG stamped 
#53 and tighten.
9)  Stick the conversion label  "This unit has 
been converted to ULPG" over top of the 
serial number decal.
10) Replace the yellow "NG" label with the red 
"ULPG" label.
11) Carefully pull out the control box.
 
NOTE: The control box is held in place with 
velcro.  
12) Remove the heat shield from the control 
box by removing the 2 screws.
15) Reverse steps 13, 12, 11, 6, 5, 4, 3 & 2.
Heat Shield
INSTALLATION