Regency IG35-LPG Manual Do Utilizador

Página de 31
12
Regency IG35 Gas Inbuilt Fireplace
16) Turn on gas supply and plug in power 
cord.
Installer Notice: 
These instructions must be left 
with the appliance.
17)    Adjusting the Outlet Pressure
       All the adjustments must be carried out  
       in the following order:
 
Remove the modulator plastic cap (A)  using 
needle nose pliers.
 
Maximum pressure: Turn the unit ON to 
its highest input rating. Screw in the nut (B) 
to increase the outlet pressure and screw it 
out to decrease it. Use a 10 mm wrench.
 
NOTE: The outlet pressure must be set to 
maximum 2.61 kPa.
 
Minimum pressure: Remove one of the 
cables connected to the electric modulator. 
While holding the nut (B) with a wrench, 
screw in the screw (C) to increase the 
pressure and screw it out to decrease it. 
Use a screwdriver 6 x 1 blade. 
 
NOTE: The outlet pressure must be set to 
minimum 0.75 kPa.
 
After carrying out all adjustments, block 
the setting screws with paint, taking care 
not to obstruct the breather orifi ce of the 
pressure.
 
Put back the modulator plastic cap.
 
WARNING: To ensure the correct opera-
tion of the modulator it is necessary that 
the plastic cap (A) is returned to its original 
location.
18) At the end of all setting and adjustment 
operations, check electrical installation and 
gas leaks.
19) Check operation of fl ame control.
20) Check for proper fl ame appearance and 
glow on logs.
C
B
A
Cable
Electric
Modulator
INSTALLATION