Mitsubishi Electronics Q170MCPU Manual Do Utilizador

Página de 274
 
 
 
7 - 5 
7   POSITIONING DEDICATED SIGNALS 
 
7.2.3 Motion Registers 
Table 7.4 Motion register list 
Device No. 
Application 
#0 
to 
User device  
(8000 points) 
#8000 
to 
Monitor device 
(640 points) 
#8640 
to 
Motion error history device 
(96 points) 
#8736 
to 
#12287 
Unusable 
(3552 points) 
           It can be used as an user device. 
 
 
7.2.4 Special Relays 
Table 7.5 Special relay list 
Device No. 
Application 
SM0 
to 
System device 
(2000 points) 
SM2000 
to 
SM2255 
System device (For replacement) 
(Note-1)
 
(256 points) 
(Note-1): For replacement from a project of Q17 HCPU(-T)/Q17 CPUN(-T)/Q17 CPU to the project of 
Q170MCPU. 
Refer to the "Q173DCPU/Q172DCPU Motion controller Programming Manual (COMMON) 
"APPENDIX 1.3 Replacement of special relays/special registers"" for details. 
 
 
7.2.5 Special Registers 
Table 7.6 Special register list 
Device No. 
Application 
SD0 
to 
System device 
(2000 points) 
SD2000 
to 
SD2255 
System device (For replacement) 
(Note-1)
 
(256 points) 
(Note-1): For replacement from a project of Q17 HCPU(-T)/Q17 CPUN(-T)/Q17 CPU to the project of 
Q170MCPU. 
Refer to the "Q173DCPU/Q172DCPU Motion controller Programming Manual (COMMON) 
"APPENDIX 1.3 Replacement of special relays/special registers"" for details.