Section 15   Serial Communication Interface with FIFO 
 
 
Page 758 of 2108 
 
R01UH0134EJ0400  Rev. 4.00 
 
 Sep 
24, 
2014 
SH7262 Group, SH7264 Group
Error handling
Receive error handling
ER = 1?
BRK = 1?
Break handling
DR = 1?
Read receive data in SCFRDR
Clear DR, ER, BRK flags 
in SCFSR,
and ORER flag in SCLSR to 0
End
Yes
Yes
Yes
No
Overrun error handling
ORER = 1?
Yes
No
No
No
   • Whether a framing error or parity error 
has occurred in the receive data that 
is to be read from the receive FIFO 
data register (SCFRDR) can be 
ascertained from the FER and PER 
bits in the serial status register 
(SCFSR).
   • When a break signal is received, 
receive data is not transferred to 
SCFRDR while the BRK flag is set. 
However, note that the last data in 
SCFRDR is H'00, and the break data 
in which a framing error occurred is 
stored.
 
Figure 15.8   Sample Flowchart for Receiving Serial Data (cont)