Section 15   Serial Communication Interface with FIFO 
 
 
Page 760 of 2108 
 
R01UH0134EJ0400  Rev. 4.00 
 
 Sep 
24, 
2014 
SH7262 Group, SH7264 Group
Figure 15.9 shows an example of the operation for reception. 
RDF
0
0/1
1
1
1
D0
D1
D7
0
0/1
1
D0
D1
D7
FER
Serial 
data
Start 
bit
Data
Parity 
bit
Stop 
bit
Start 
bit
Data
Parity 
bit
Stop 
bit
RXI interrupt 
request
One frame
Data read and RDF flag 
read as 1 then cleared to 0 
by RXI interrupt handler
ERI interrupt request 
generated by receive 
error
Idle state 
(mark state)
 
Figure 15.9   Example of Receive Operation 
(8-Bit Data, Parity, 1 Stop Bit) 
5.  When modem control is enabled in channel 3, the 
RTS signal is output when SCFRDR is 
empty. When 
RTS is 0, reception is possible. When RTS is 1, this indicates that SCFRDR 
exceeds the number set for the RTS output active trigger. 
 
Figure 15.10 shows an example of the operation when modem control is used. 
RTS
0
1
0/1
D0
D1
D2
D7
D0
D1
0/1
D7
0
Serial data
RxD
Start 
bit
Parity
bit
Start 
bit
Parity 
bit
 
Figure 15.10   Example of Operation Using Modem Control (
RTS