Renesas R5S72622 Manual Do Utilizador

Página de 2152
 
Section 33   Power-Down Modes 
R01UH0134EJ0400  Rev. 4.00  
 
Page 1809 of 2108 
Sep 24, 2014 
 
 
 
SH7262 Group, SH7264 Group 
(3)  Note on Release from Software Standby Mode 
Release from software standby mode is triggered by interrupts (NMI and IRQ) or resets (manual 
reset and power-on reset). If, however, a SLEEP instruction and an interrupt other than NMI and 
IRQ are generated at the same time, software standby mode may be canceled due to acceptance of 
the interrupt. 
When initiating a transition to software standby mode, make settings so that interrupts are not 
generated before execution of the SLEEP instruction. 
(4)  Note on Canceling Software Standby Mode 
After software standby mode is canceled, unstable clock pulses are output from the CKIO pin 
during oscillation settling time. To prevent malfunction due to the unstable pulses, bits 13 and 12 
in FRQCR should be modified.