Section 20   Controller Area Network 
Page 1074 of 2108 
 
R01UH0134EJ0400  Rev. 4.00 
 
 Sep 
24, 
2014 
SH7262 Group, SH7264 Group
When this module recognises the end of the Arbitration field while receiving a message, it starts 
comparing the received identifier to the identifiers set in the Mailboxes, starting from Mailbox-31 
down to Mailbox-0. It first checks the MBC if it is configured as a receive box, and reads LAFM, 
and reads the CAN-ID of Mailbox-31 (if configured as receive) to finally compare them to the 
received ID. If it does not match, the same check takes place at Mailbox-30 (if configured as 
receive). Once this module finds a matching identifier, it stores the number of Mailbox-[N] into an 
internal buffer, stops the search, and goes back to idle state, waiting for the EndOfFrame (EOF) to 
come. When the 6
th
 bit of EOF is notified by the CAN Interface logic, the received message is 
written or abandoned, depending on the NMC bit. No modification of configuration during 
communication is allowed. Entering Halt Mode is one of ways to modify configuration. If it is 
written into the corresponding Mailbox, including the CAN-ID, i.e., there is a possibility that the 
CAN-ID is overwritten by a different CAN-ID of the received message due to the LAFM used. 
This also implies that, if the identifier of a received message matches to ID + LAFM of 2 or more 
Mailboxes, the higher numbered Mailbox will always store the relevant messages and the lower 
numbered Mailbox will never receive messages. Therefore, the settings of the identifiers and 
LAFMs need to be carefully selected. 
With regards to the reception of data and remote frames described in the above flow diagram the 
clearing of the UMSR flag after the reading of IRR is to detect situations where a message is 
overwritten by a new incoming message stored in the same mailbox (if its NMC = 1) while the 
interrupt service routine is running. If during the final check of UMSR a overwrite condition is 
detected the message needs to be discarded and read again. 
In case UMSR is set and the Mailbox is configured for overrun (NMC = 0) the message is still 
valid, however it is obsolete as it is not reflecting the latest message monitored on the CAN Bus. 
Please access the full Mailbox content before clearing the related RXPR/RFPR flag. 
Please note that in the case a received remote frame is overwritten by a data frame, both the 
remote frame receive interrupt (IRR2) and data frame received interrupt (IRR1) and also the 
Receive Flags (RXPR and RFPR) are set. In an analogous way, the overwriting of a data frame by 
a remote frame, leads to setting both IRR2 and IRR1. 
When a message is received and stored into a Mailbox all the fields of the data not received are 
stored as zero. The same applies when a standard frame is received. The extended identifier part 
(EXTID[17:0]) is written as zero.