Renesas R5S72621 Manual Do Utilizador

Página de 2152
 
Section 11   Multi-Function Timer Pulse Unit 2 
 
R01UH0134EJ0400  Rev. 4.00  
 
Page 645 of 2108 
Sep 24, 2014 
 
 
 
SH7262 Group, SH7264 Group 
(27)  Operation when Error Occurs during Reset-Synchronized PWM Mode Operation, and 
Operation is Restarted in PWM Mode 1 
Figure 11.141 shows an explanatory diagram of the case where an error occurs in reset-
synchronized PWM mode and operation is restarted in PWM mode 1 after re-setting. 
1
RESET
2
TOCR
3
TMDR
(RPWM)
5
PFC
(MTU2)
4
TOER
(1)
6
TSTR
(1)
7
Match
8
Error 
occurs
9
PFC
(PORT)
10
TSTR
(0)
11
TMDR
(PWM1)
12
TIOR
(1 init
0 out)
13
PFC
(MTU2)
14
TSTR
(1)
MTU2 module output
TIOC3A
TIOC3B
TIOC3D
Port output
PE9
PE8
PE11
Not initialized (TIOC3B)
Not initialized (TIOC3D)
High-Z
High-Z
High-Z
 
Figure 11.141   Error Occurrence in Reset-Synchronized PWM Mode, 
Recovery in PWM Mode 1 
1 to 10 are the same as in figure 11.140. 
11.  Set PWM mode 1. (The positive phase output from this module is low, and negative phase 
output is high.) 
12.  Initialize the pins with TIOR. (In PWM mode 1, the TIOC *B side is not initialized.) 
13.  Set the multi-function timer pulse unit 2 output with the general I/O port. 
14.  Operation is restarted by TSTR.