Renesas R5S72621 Manual Do Utilizador

Página de 2152
 
Section 11   Multi-Function Timer Pulse Unit 2 
 
R01UH0134EJ0400  Rev. 4.00  
 
Page 647 of 2108 
Sep 24, 2014 
 
 
 
SH7262 Group, SH7264 Group 
(29)  Operation when Error Occurs during Reset-Synchronized PWM Mode Operation, and 
Operation is Restarted in Reset-Synchronized PWM Mode 
Figure 11.143 shows an explanatory diagram of the case where an error occurs in reset-
synchronized PWM mode and operation is restarted in reset-synchronized PWM mode after re-
setting. 
1
RESET
2
TOCR
3
TMDR
(RPWM)
5
PFC
(MTU2)
4
TOER
(1)
6
TSTR
(1)
7
Match
8
Error 
occurs
9
PFC
(PORT)
10
TSTR
(0)
11
PFC
(MTU2)
12
TSTR
(1)
13
Match
MTU2 module output
TIOC3A
TIOC3B
TIOC3D
Port output
PE9
PE8
PE11
High-Z
High-Z
High-Z
High-Z
High-Z
High-Z
 
Figure 11.143   Error Occurrence in Reset-Synchronized PWM Mode, 
Recovery in Reset-Synchronized PWM Mode 
1 to 10 are the same as in figure 11.140. 
11.  Set the multi-function timer pulse unit 2 output with the general I/O port. 
12.  Operation is restarted by TSTR. 
13.  The reset-synchronized PWM waveform is output on compare-match occurrence.