Enviro 1200 Fireplace Freestanding Manual Do Utilizador

Página de 50
32
Installation
Figure 35: Attaching removable flue.
Figure 36: Leveling leg.
S
URROUND
 P
ANEL
 S
EALED
 I
NSTALLATION
 F
OR
 USA O
NLY
 - I
NSERT
:
Before  starting  this  type  of  installation 
refer  to  I
NSTALLATION
  -  M
ASONRY
  F
IREPLACE
 
I
NSTALLATION
  -  I
NSERT
  for  additional 
information.  For  clearances  refer  to 
S
PECIFICATIONS
  -  C
LEARANCES
  T
O
  C
OMBUSTIBLES
 
- 1200 I
NSERT
 and S
PECIFICATIONS
 - C
LEARANCES
 
T
O
 C
OMBUSTIBLES
 - 1700 I
NSERT
1.  Before  the  face  plate  is  installed 
onto  the  unit,  glue  a  6”  (150mm) 
wide  R20  fiberglass  insulation  strip 
around  the  perimeter  of  the  back  of 
the  panels  using  RTV  silicon  or  stove 
gasket  cement.  When  the  face  plate 
is installed onto the unit the insulation 
must  overlaps  the  fireplace  opening 
to  form  a  seal  between  the  masonry 
fireplace and the unit’s face plate. Let 
the silicon or cement dry.
2.  To make the installation of the surround 
panel onto the unit easy have the unit 
6” (150mm) out from the fireplace, 
3.  Push  the  insert  into  the  fireplace, 
allowing  the  insulation  to  form  a  seal 
between the panels and the fireplace. 
Tuck any exposed insulation behind the 
face plate.
Figure 37: Installation with Surround Sealed.
Masonry Fireplace
Mantel
Damper Removed
or Fastened Open
Surround Panel
USA 16” (406 mm)
CND 18” (450 mm)
Insulation Around the
Back of the Face Plate
����� �� ��� ���� ���� �� ������������ ��
��������� ���� ������� ���� � �������
��������������� ���� �� �� ��� � ������� ��
��� ������ ����� �� �� �� ��� ������ ���� �����
���� ������� ��� ��� ���� ���������� ����
��� ��� ��������� �� ������� �������������
�������� ������������� ��� ���� ���������
�� ������� ��� �� ��� ������� �� ������ ��������
�� ��������