Installation
I
NSTALLATION
 U
SING
 A B
LOCK
-O
FF
 P
LATE
 F
OR
 USA O
NLY
 - I
NSERT
:
If this unit is to be installed into a masonry fireplace or a zero-clearance fireplace with a direct connection 
you  must  install  a  non-combustible  seal-off  device  such  as  a  block-off  plate  or  damper  adapter.  By 
installing a block-off plate you seal the chimney, ensuring that no smoke enters the home and sealing the 
chimney to encourage draft. To construct a block-off plate follow the below steps.
1.  Determine where the block-off plate will be installed; above the top of the firebox (it must be high 
enough to easily install the connection pipe) but below the damper area. Look for a location that 
A
B
C
D
Front of fireplace opening.
is  level  and  in  an  area  where  the  plate  can  be  mounted 
easily. 
 
The measurement that will be needed are as followed (refer 
to Figure 38 and 39):
A - The width at the front of the firebox at the height where 
the block-off plate will be installed.
B - The width at the back of the firebox at the height where 
the block-off plate will be installed.
C - Then  depth  of  the  block-off  needed  (the  distance 
between A and B).
D - The distance of the center of the flue to the front of the 
fireplace opening. Refer to Step 3. 
 
NOTE: In general masonry fireplaces have square fireboxes 
while zero-clearance (metal) fireplaces have domed firebox 
tops. Therefore zero-clearance block-off plates may be more 
difficult to install. Insulation may be used around the edges 
to simplify sealing the plate. 
2.  Create a cardboard template of the dimensions with 2” (51 
cm) wide flanges on each side. These flanges will be used to 
mount the block-off plate to the inside of the firebox. Bend 
the flanges downwards on the template and place it inside 
the  fireplace.  Continue  on  if  the  template  fits  correctly  in 
its  planned  location.  If  the  template  does  not  fit,  make  a 
new template with the required corrections until it does fit 
correctly.
3.  With the template in place, mark the location for the center 
of the flue pipe when the unit is in place. If installing a 1200 
the distance will be approximately 81⁄4” or 9 
15
/
16
” back from 
the fireplace opening. If installing a 1700 the distance will 
be approximately 123⁄4” or 14 
7
/
16
” back from the fireplace 
opening. Remove the template and cut a 61⁄4” diameter hole 
centered on this mark. 
4.  Using the template make the block-off plate of 24 gauge or 
thicker steel. Drill two (2) holes in each flange for mounting 
the plate.
Figure 38: 3D of Dimensions needed from 
the Fireplace.
Figure 39: Layout of the Block-Off Plate.