VENTING INSTALLATION 
INSTRUCTIONS
 WARNING: Read all instruc-
tions completely and thoroughly 
before  attempting  installation. 
Failure to do so could result in 
serious injury, property damage 
or loss of life. 
 WARNING: Seal all connec-
tions  with  high  temperature 
silicone every time a vent con-
nection is made. Before joining 
elbows  or  pipes,  apply  a  bead 
of  high  temperature  silicone 
sealant  to  the  male  end  of  the 
elbow or pipe. High temperature 
silicone must also be used to re-
seal any connections after main-
tenance to venting system.
NOTICE: Failure to follow these in-
structions will void the warranty. 
NOTICE: Do not seal termination 
cap to vent pipe. Cap must be 
removable  for  vent  inspection 
and maintenance.
INSTALLATION PRECAUTIONS
Consult local building codes before beginning the 
installation. The installer must make sure to select 
the proper vent system for installation. Before 
installing vent kit, the installer must read this 
fireplace manual and vent kit instructions.
Only a qualified service person should install 
venting system. The installer must follow these 
safety rules:
•  Wear gloves and safety glasses for protection
•  Use extreme caution when using ladders or 
when on roof tops
•  Be aware of electrical wiring locations in walls 
and ceilings
The following actions will void the warranty on 
your venting system:
•  Installation of any damaged venting component
•  Unauthorized modification of the venting sys-
tem (Do not cut or alter vent components)
•  Installation of any component part not manu-
factured or approved by DESA
•  Installation other than as instructed by these 
instructions
 WARNING: This gas fireplace 
and vent assembly must be vented 
directly to the outside. The venting 
system must NEVER be attached 
to a chimney serving a separate 
solid fuel burning appliance. Each 
direct-vent  gas  appliance  must 
use a separate vent system. Do not 
use common vent systems.
INSTALLATION PLANNING
There are two basic types of direct-vent installation:
•  Horizontal Termination 
•  Vertical Termination 
It is important to select the proper length of vent 
pipe for the type of termination you choose. It is 
also important to note the wall thickness. 
For Horizontal Termination:
 Select the amount of 
vertical rise desired. The horizontal run of venting 
must have 1/4" rise for every 12" of run towards 
the termination.  
  WARNING:  Never  run  the 
vent  downward  as  this  may 
cause excessive temperatures 
which could cause a fire.
You may use one or two 90° elbows in this vent 
configuration. See Horizontal Termination Con-
figurations on page 13.
For  Vertical  Termination: 
Measure the distance 
from the fireplace flue outlet to the ceiling. Add 
the ceiling thickness, the vertical rise in an attic or 
second story, and allow for sufficient vent height 
above the roof line. You may use one or two 90° 
elbows in this vent configuration. See Vertical 
Termination Configurations on page 16.
Note: 
You may use two 45° elbows in place of a 
90° elbow. You must follow rise to run ratios when 
using 45° elbows.
For two-story applications, firestops are required at 
each floor level. If an offset is needed in the attic, 
additional pipe and elbows will be required.
You may use a chase with a vent termination with 
exposed pipe on the exterior of the house. See In-
stalling Vent System in a Chase, page 11.