Jacuzzi J-210 Manual Do Utilizador

Página de 60
J-200 Series
all north american J-210 Convertible Models (60 hz)
120V/15A†
240V/30A†
240V/40A
Circuit Breaker:
15A†, 1-Pole 30A†, 2-Pole 40A, 2-Pole
Number of Wires:
3 (15A GFCI 
Cord US 
Only*)
4 (Hard Wire 
Only)
4 (Hard Wire 
Only)
Frequency:
60 Hz
60 Hz
60 Hz
Current Draw:
12A
21A
30A
*  all Canadian spas must be hard wired per Csa Canadian standards. 
(page 8)
  In 15A/30A configuration, the heater will not operate while the jets 
pump is running in high speed. The factory setting is 120V/15A.
  In 40A configuration, remove jumper JP1-2 on the board, to allow the 
heater to operate when the jets pump is running in high speed.
CauTIon (For 4-wire 240 vaC Heater operation): move the 
red wire on the main terminal strip (TB1) from position #1 to 
position #3. make certain wires are connected exactly as shown 
in Figure-D (page 18
) before applying power. Failure to do so will 
result in damage to the circuit board and/or related components 
and void the manufacturer’s warranty.
export J-270 and J-280 models (50 Hz)
230V/20A*
230V/30A**
230V/40A***
Circuit Breaker:
20A*
30A**
40A***
Number of Wires:
3
3
3
Frequency:
50 Hz
50 Hz
50 Hz
Current Draw:
15A
23A
29A
* 
In 20A configuration, the heater will not operate while either jets 
pump is running in high speed. This is the factory setting. Note: 
pump 2 runs only in high speed.
**  In 30A configuration, the heater will operate while one jets pump is 
running in high speed. Note: pump 2 runs only in high speed.
***  In 40A configuration the heater will operate while both jets pumps 
are running in high speed.