Hoshizaki KML-250MAH Guia Do Utilizador

Página de 109
39
[d] CONTROLS AND ADJUSTMENTS
The Dip Switch is factory-adjusted to the following positions:
FOR MODELS WITH THERMOSTAT:
Switch Nos. 1 and 2:
Used for adjustment of the Defrost Timer.
The Defrost Timer starts counting when the Thermistor reads a certain temperature
           at the Evaporator outlet.
Switch Nos. 3 and 4:
Used for adjustment of the Drain Timer.
When a freeze cycle is completed, the Pump Motor stops, and the icemaker
           resumes operation in 2 seconds.  Then the Pump Motor drains the Water Tank
           for the time determined by the Drain Timer.  The Drain Timer also determines the
           time to restrain completion of a defrost cycle, i.e. the minimum defrost time.
Switch Nos. 5 and 6:
Used for adjustment of the Drain Counter.
The Pump Motor drains the Water Tank at the frequency determined by the Drain
          Counter.
FOR MODELS WITH MECHANICAL BIN CONTROL:
DIP SWITCH NO.
1
2
3
4
5
6
7
8
9
10
KML-250 MAH
OFF
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
KML-250 MWH
OFF
OFF
OFF
ON
ON
ON
OFF
OFF
OFF
ON
350M_F, 350M_H
OFF
OFF
OFF
ON
ON
ON
OFF
OFF
OFF
ON
KML-450M_F, M_H
KML-600MAF, MAH
KML-600MWF, MWH
OFF
OFF
OFF
OFF
ON
ON
OFF
OFF
OFF
ON
KML-600MRF, MRH
ON
OFF
OFF
OFF
ON
ON
OFF
OFF
OFF
ON
DIP SWITCH NO.
1
2
3
4
5
6
7
8
9
10
KML-250 MAH
OFF
OFF
OFF
ON
ON
ON
ON
OFF
ON
OFF
KML-250 MWH
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
ON
350M_F, 350M_H
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
ON
KML-450M_F, M_H
KML-600MAF, MAH
KML-600MWF, MWH
OFF
OFF
OFF
OFF
ON
ON
ON
OFF
OFF
ON
KML-600MRF, MRH
ON
OFF
OFF
OFF
ON
ON
ON
OFF
OFF
ON