Hoshizaki HUR40a Manual Do Utilizador

Página de 64
4
2. Temperature Display
• Displays the cabinet temperature. The factory setting is °F. To change the display to the 
°C scale, see "a) Switching the Display Between Fahrenheit and Celsius (F5)" below.
• The cabinet temperature is updated every 30 seconds.
• During defrost, "dF" is displayed in place of the cabinet temperature.
a) Switching the Display Between Fahrenheit and Celsius (F5)
The factory setting is °F. To change the display to °C, follow the steps below. 
1) Press and hold both the 
 button and the 
 unmarked, blank button for 5 seconds. 
"F5" appears in the display window. (If "F0" is displayed, press the MANUAL 
DEFROST button until "F5" appears.)
) Press the 
 unmarked, blank button to display the current setting (default: "F"). Press 
the 
 up or 
 down button to switch to °C. Press the 
 unmarked, blank button 
again to save the setting.
3) Press and hold both the 
 button and the 
 unmarked, blank button for 5 seconds. 
The cabinet temperature will be displayed using the newly saved temperature scale.
4) Affix the "°C" label supplied with the unit to the display panel, covering "°F" but not the 
display window.
b) Adjusting the Setpoint Temperature
The setpoint temperature is the temperature at which the compressor turns on. To set 
the setpoint temperature, follow the steps below.
1)  Press the 
 button to display the current setpoint temperature.
)  To change the setpoint, press and hold the 
 button while pressing the  
 up or 
 
down button to raise or lower the setpoint. 
Model
Allowable Setpoint Range
Default
Refrigerator (auxiliary code Q5 and earlier)
+1 to +53°F
(-6 to +1°C)
39°F
(4°C)
Refrigerator (auxiliary code Q6 and later)
37°F
(3°C)
Freezer (Door)
-13 to +19°F
(-5 to -7°C)
0°F
(-18°C)
Freezer (Drawer)
°F
(-17°C)
3)  After 10 seconds, the new setpoint will be saved automatically.
Note: For refrigerators, the temperature differential for the compressor to turn off is 
-4.5°F (-.5°C) for auxiliary code Q5 and earlier and -3.6°F (-.0°C) for auxiliary 
code Q6 and later. For 1-section freezers, it is -6.3°F (-3.5°C) and for -section 
freezers, it is -3.6°F (-.0°C).