8
Problem
Possible Cause
Remedy
[4] Cabinet inside 
temperature too 
high; 
compressor will 
not start.
a) Thermistor
1. Defective.
1. Check and replace.
b) Compressor Relay
1. Defective. (LED 4 is ON. 
115V to relay coil.)
1. Check and replace.
c) Circuit Board
1. Defective. (LED 4 is OFF. 
Compressor relay coil not 
energized at 115V.) 
1. Replace. 
[5] Cabinet 
temperature too 
high.
a) Setpoint
1. Incorrect.
1. Correct setpoint.  
Factory defaults: 
Freezer -3°F 
Refrigerator 36°F
b) Door
1. Not sealing, or open for long 
intervals.
1. Check for sealing, check for door 
open at time of warm cabinet 
temperature.
c) Defrost
1. Not enough defrosts 
occurring per day. Operation 
in humid conditions. 
1. 
Freezer: See "D.1.b) Defrost 
Frequency."
Refrigerator: See  "D.1.b) 
Defrost Frequency."
3. Check thermistor reading and 
position.
d) Refrigerant
1. Leak.
1. Repair leak and recharge.
e) Fan Motor 
1. Defective.
1. Check and replace.
f) Air Filter
1. Clogged.
1. Clean.
g) Condenser
1. Dirty.
1. Clean.
h) Thermistor
1. Defective.
1. Check and replace.
i) Control Board
1. Defective.
1. Replace.
[6] Cabinet 
temperature 
display 
indicator does 
not illuminate 
properly.
a) Board Connection
1. Bad connection between 
control board and display 
board.
1. Check connection.
b) Display Board 
1. Defective.
1. Replace.
c) Control Board
1. Defective.
1. Replace.
[7] Cabinet inside 
temperature too 
low.
a) Thermistor 
1. Defective.
1. Check and replace.
b) Compressor Relay
1. Defective; contacts welded.
1. Replace.
c) Circuit Board
1. Defective.
1. Replace.
[8] Evaporator does 
not defrost 
completely.
a) Defrost Thermistor 
1. Defective.
1. Check and replace.
b) Defrost
1. Not enough defrosts 
occurring per day. Operation 
in humid conditions. 
1. 
Freezer: See "D.1.b) Defrost 
Frequency."
Refrigerator: See  "D.1.b) 
Defrost Frequency." 
3. Check thermistor reading and 
position.
c) Defrost Heaters
1. Defective. (E3 should be 
displayed)
1. 
Freezer: Replace heaters. 
Reset E3 by pressing control 
board "ALARM RESET."
d) Safety Defrost 
Thermostat 
1. Defective, turning off heaters 
prematurely, or fused open. 
(E3 should be displayed)
1. 
Freezer: Replace safety defrost 
thermostat. 
Reset E3 by pressing control 
board "ALARM RESET."