Hoshizaki fh1-ssb Guia Do Utilizador

Página de 23
1
B. Startup
CAUTION
All parts are factory adjusted. Improper adjustments may result in failure or loss 
of product.
Supply power to the unit. Open the front panel for access to the power switch—located 
on the front of the control box—and move the switch to the "ON" position. Allow the unit 
to pull down prior to loading it with food products.
IMPORTANT
• TempGuard Refrigerators and Freezers: At startup, there is a  1/ minute 
delay before the compressor starts.
Note: On Dual Temp units, there is a delay of approximately 10 seconds 
between one compressor start (i.e. freezer) and the next compressor 
start (i.e. refrigerator).
• SafeTemp Refrigerators: At startup, there is a  minute delay before the 
compressor starts.
• SafeTemp Freezers: At startup, a defrost is initiated.
C. Cabinet Temperature
1. TempGuard Models
a) Temperature Display
• The cabinet temperature is displayed on the control panel. See Fig. 7. The display 
default is °F, but it can be changed to read °C. To change, see "II.C.1.c) Changing the 
Temperature Display Scale (°F or °C)".
• The cabinet temperature is updated every 0 seconds.
Front Panel
Control 
Panel
Door
Arrow
Fig. 7