Hoshizaki fh1-ssb Guia Do Utilizador

Página de 23
7
3. Electrically Heated Condensate Pan
(if applicable)
The electrically heated condensate pan is used to evaporate condensate water from the 
unit. To install the electrically heated condensate pan, follow the directions below.
WARNING
Verify that power to the unit is disconnected before installing pan.
1) Remove the panel that covers the recess 
in the back of the unit. See Fig. 4.
) Route the wire found in the recess in the 
back of the unit through the wire cover 
and install the wire cover to the unit.
3) Plug the cord (wire) routed in step  into 
the female plug of the heated pan.
4) Replace the panel to cover the recess in 
the back of the unit.
5) Clip the heated pan onto the mounting 
plate and attach to the panel that covers 
the recess in the back of the unit using 
the 4 screws provided.
6) Install the plug cover to the rear of the 
unit.
2. Overflow Pan
(if applicable)
Units are supplied with an energy efficient automatic condensate water evaporation 
system. The overflow pan is supplied for the unlikely event that water cannot evaporate 
at a high enough rate. If water is found in the overflow pan, call your Hoshizaki Certified 
Service Representative for assistance. To install the overflow pan, follow the directions 
below.
1) Attach the overflow pan's brackets by 
engaging the tab on the bracket through 
the hole in the bottom of the unit and 
securing with the four mounting screws 
provided. See Fig. 3.
) Slide the plastic pan into place under the 
vinyl hose on the back of the cabinet. 
Cabinet
Overflow Bracket
Mounting Screws
Overflow Pan
Tab
Cover Panel
Heated Pan
Mounting 
Plate
Plug
Plug Cover
Wire Cover
Wire
Cabinet
Fig. 3