Adtran 550 Guia Do Utilizador
Section 4 User Interface Guide
ATLAS 550 System Manual
154
© 2004 ADTRAN, Inc.
61200305L2-1B
M
ODULES
(FXO-4/8) > S
TATUS
> T
X
ABCD
Read security: 5
Transmit Signaling bits have local significance only, and represent signaling between the ATLAS 550
Controller and the voice port if the port is configured in the
Controller and the voice port if the port is configured in the
D
IAL
P
LAN
. The bit pattern is formatted
ESF
RBS
.
M
ODULES
(FXO-4/8) > T
EST
Write security: 4; Read security: 5
The
T
EST
options initiate different types of tests and display test results.
M
ODULES
(FXO-4/8) > T
EST
> P
ORT
Write security: 5; Read security: 5
Displays the operating port. There are 4 available interfaces on the Quad FXO Option Module and 8 on the
Octal FXO Option Module.
Octal FXO Option Module.
M
ODULES
(FXO-4/8) > T
EST
> T
EST
2W
Write security: 4; Read security: 5
Activates 2W (FXO) tests on a per-port basis. Options include
O
FF
, L
OOP
O
PEN
, L
OOP
C
LOSED
,
and
R
ING
G
ROUND
. The 2W tests will disrupt the active call on the selected FXO port. Table 4 displays the state of
the 2W conductors during each test.
M
ODULES
(FXO-4/8) > T
EST
> TX ABCD
Write security: 4; Read security: 5
Forces the Transmit Robbed Bit Signaling (Tx RBS) to a specified value. Values include
O
FF
, 0000, 0101,
1010,
or
1111
.
M
ODULES
(FXO-4/8) > T
EST
> 1
K
H
Z
T
ONE
Write security: 3; Read security: 5
Sends a 1kHz tone into the following locations, based on test selection:
N
EAR
sends the tone out the 2W
FXO port, while
F
AR
sends the tone into the digital PCM stream of the ATLAS 550 controller. These tests
are useful for verifying a voice path.
Table 4. FXO 2W State Table
T
EST
T
IP
O
UTPUT
R
ING
O
UTPUT
Off
No test active
No test active
Loop Open
High impedance
High impedance
Loop Closed
Off-hook impedance
Off-hook impedance
Ring Ground
High impedance
R to ground
Calls may be affected when activating the Tx ABCD test. This test is not valid when the
port is used in the
port is used in the
D
IAL
P
LAN
.