Adtran 4305 Instrução De Instalação

Página de 56
 Option Modules
NetVanta 4305 Hardware Installation Guide
 26
Copyright © 2006 ADTRAN, Inc.
61200890L1-34H
NetVanta T1/FT1 NIM (P/N 1202862L1)
The T1/FT1 NIM (shown in Figure 5) provides a T1 (full T1 or fractional T1) WAN interface for the 
NetVanta 4305. See Table A-4 on page 50 for the WAN-T1 connector pinouts and see Table A-4 on page 
50 fo
r the DBU connector pinouts. An optional DIM is required for dial backup applications.
Figure 5.  NetVanta T1/FT1 NIM
WAN-T1
DBU
Features and Specifications
Operating Modes
Frame Relay, Multilink Frame Relay
PPP, Multilink PPP
HDLC
T1/FT1 Interface
Supported Standards: AT&T TR 62411, 
AT&T TR 65016, ANSI T1.403, 
Bellcore TR 194
Line Rate: 1.544 Mbps +75 bps
Line Code: AMI or B8ZS
Framing: D4 (SF) or ESF
FT1 Line Rate: DS0 channelized (multiples 
of 64 kbps)
Input Signal: 0 to -36 dB (DS1)
Line Build-Out: 0, -7.5, -15, -22.5 dB 
(long), 0 to 655 ft (short)
DS0 Assignment: Programmable
Connector: RJ-48C
Clock Source
Network
Internal
Diagnostics
Test Pattern Generation and Detection: 
511, QRSS, all ones, all zeros
Network loopbacks (local and remote); 
responds to both inband and FDL loop 
codes
Alarm generation and detection
Network and user sets of performance data 
(15 minutes and 24 hours)
Compliance
ACTA/FCC Part 68
IC CS-03
UL/CUL 60950
Environmental
Operating Temperature: 0°C to 50°C
Storage Temperature: -20°C to 70°C
Relative Humidity: Up to 95 percent, 
noncondensing
Physical
Dimensions: 2.75-inch W x 4.25-inch D