Preparing for the Installation
SuperLoader™ 3 Quick Start Guide
Choose a location that meets the following criteria:
Preparing for the Installation
Before you begin the installation procedure in this section, make the following
preparations as described in this section:
•
•
•
•
Providing Necessary Tools
0
Provide the following tools for unpacking and installing the autoloader:
• #2 Phillips screwdriver
• Level
• Antistatic wrist strap
• Level
• Antistatic wrist strap
Criteria
Description
Rack requirements
Standard 19-inch rack
Room temperature
10–35° C (50–95° F)
Power source
AC power voltage: 100–127 VAC; 200–240 VAC
Line frequency: 50–60 Hz
Line frequency: 50–60 Hz
Note:
Locate the AC outlet near the autoloader. The AC
power cable is the product’s main disconnect device and must
be easily accessible at all times.
be easily accessible at all times.
Weight
14.1 kg (31 lb.) unloaded
17.2 kg (38 lb.) loaded with 2 magazines, 16 cartridges
17.2 kg (38 lb.) loaded with 2 magazines, 16 cartridges
Air Quality
Minimize sources of particulate contamination. Avoid areas
near frequently used doors and walkways, cooling or exhaust
vents, stacks of supplies that collect dust, printers, and
smoke-filled rooms.
near frequently used doors and walkways, cooling or exhaust
vents, stacks of supplies that collect dust, printers, and
smoke-filled rooms.
Caution:
Excessive dust and debris can damage tapes and
tape drives.
Humidity
20–80% RH (non-condensing)
Clearance
Back: Minimum of 43.2 cm (17 in.)
Front: Minimum of 68.6 cm (27 in.)
Sides: Minimum of 5.08 cm (2 in.)
Front: Minimum of 68.6 cm (27 in.)
Sides: Minimum of 5.08 cm (2 in.)