Champion pp-3 Manual Do Utilizador
C O N T R O L P A N E L S
Parameter
Mnemonic
Parameter
Name
Description
Table 1 Default
Value
(Celsius)
Table 2 Default
Value
(Fahrenheit)
Units
sp
Setpoint
Temperature Set Point
46ºc 115 ºF
Degrees
t
Timer 1
Change Water Cycle
Time
4.00 4.00
H:MM
t
2
Timer 2
Soap Dispensing Delay
Time
2.00 2.00
M:SS
t
3
Timer 3
Soap Dispensing Time
0.30 0.30
M:SS
Al.1
Alarm 1
Alarm 1 Set Point
107 ºc
225
º
F
Degrees
Hs.1
Hysteresis Alarm
1
Hysteresis
0.1 0.1
%
Al..2
Alarm 2
Alarm 2 Set Point
72
º
c 160
º
f
Degrees
Hs..2
Hysteresis
Alarm 2 Hysteresis
0.1 0.1
%
hs
Hysteresis On/Off
Hysteresis
0.1 0.1
%
r
l
Range
Low
Set Point Low Limit
38
º
c 100
º
f
Degrees
r
h
Range
High
Set Point High Limit
52
º
c 125
º
f
Degrees
Setup Mode Parameter Table
Configuration Mode –
c
n
f
Enter the supervisor mode and press the UP or DOWN buttons until cnf is displayed.
Press the TEMP button to select.
Press the TEMP button to select.
When prompted for a password (p55), use the UP and DOWN buttons to select 415. Press
the TEMP button to enter in the value.
the TEMP button to enter in the value.
Press the TEMP button to toggle between the parameters that are available, see parameter
table below.
table below.
The parameter name and its value will be swapped in and out of the display. Press the UP
and DOWN button to change the parameters value. Once a value has been changed, press
the TEMP key to lock in this value and move on to the next parameter. If you do not press
the TEMP key within three seconds after changing a parameters value, the new value will
not be saved.
and DOWN button to change the parameters value. Once a value has been changed, press
the TEMP key to lock in this value and move on to the next parameter. If you do not press
the TEMP key within three seconds after changing a parameters value, the new value will
not be saved.
Exit the supervisor mode when done with the setup mode.
NOTE:
See Supervisor Mode section
on how to exit.
16