C O N T R O L   P A N E L S  
 
Parameter 
Mnemonic 
Parameter 
Name 
Description 
Table 1 Default 
Value  
(Celsius) 
Table 2 Default 
Value 
(Fahrenheit) 
Units 
sp 
Setpoint 
Temperature Set Point 
46ºc 115 º
Degrees 
Timer 1 
Change Water Cycle 
Time 
4.00 4.00 
H:MM 
t
Timer 2 
Soap Dispensing Delay 
Time 
2.00 2.00 
M:SS 
t
3
 
Timer 3 
Soap Dispensing Time 
0.30 0.30 
M:SS 
Al.1 
Alarm 1 
Alarm 1 Set Point 
107 º
225
 º
Degrees 
Hs.1 
Hysteresis Alarm 
Hysteresis 
0.1 0.1 
Al..2 
Alarm 2 
Alarm 2 Set Point 
72
 º
c 160
 º
Degrees 
Hs..2 
Hysteresis 
Alarm 2 Hysteresis 
0.1 0.1 
hs 
Hysteresis On/Off 
Hysteresis 
0.1 0.1 
r
Range 
Low 
Set Point Low Limit 
38
 º
c 100
 º
Degrees 
r
Range 
High 
Set Point High Limit 
52
 º
c 125
 º
Degrees 
Setup Mode Parameter Table 
 
Configuration Mode – 
c
n
Enter the supervisor mode and press the UP or DOWN buttons until cnf  is displayed. 
Press the TEMP button to select. 
When prompted for a password (p55), use the UP and DOWN buttons to select 415. Press 
the TEMP button to enter in the value. 
Press the TEMP button to toggle between the parameters that are available, see parameter 
table below.  
The parameter name and its value will be swapped in and out of the display. Press the UP 
and DOWN button to change the parameters value. Once a value has been changed, press 
the TEMP key to lock in this value and move on to the next parameter.  If you do not press 
the TEMP key within three seconds after changing a parameters value, the new value will 
not be saved. 
Exit the supervisor mode when done with the setup mode. 
NOTE:
 See Supervisor Mode section 
on how to exit. 
 
 